paratecSGL is available for download through SVN repository at 
https://civet.berkeley.edu/svn/CODES/paratecSGL/
(only for authorized users).

To build with support for BerkeleyGW output, in arch.mk set the
line GWWFNPATH to BerkeleyGW/library, and add -DBGW to M4OPTLIBS.

Full documentation for PARATEC 5.1:
http://www.tcm.phy.cam.ac.uk/~jry20/paratec/doc/doc.html

Literature:
* B. G. Pfrommer, J. Demmel, and H. Simon, "Unconstrained Energy Functionals
  for Electronic Structure Calculations," J. Comp. Phys. 150, 287 (1999).
* B. G. Pfrommer, M. Cote, S. G. Louie, and M. L. Cohen, "Relaxation of
  Crystals with the Quasi-Newton Method," J. Comp. Phys. 131, 233 (1997).
* Mathieu Taillefumier, Delphine Cabaret, Anne-Marie Flank, and Francesco
  Mauri, "X-ray absorption near-edge structure calculations with
  pseudopotentials: Application to the K-edge in diamond and alpha-quartz,"
  Phys. Rev. B 66, 195107 (2002).
* http://cmsn.drupalgardens.com/sites/cmsn.drupalgardens.com/files/CMSN_Newsletter_Vol2No2.pdf

[An older version was available at http://www.nersc.gov/projects/paratec.
PARATEC 5.1 produces only the old GW wavefunction format, incompatible
with this version of BerkeleyGW. However, you can convert them to the
new format using MeanField/Utilities/convert_old_to_new.x.]

The pseudopotentials for PARATEC can be generated with 
the fhi98PP program which is available for download at 
http://www.fhi-berlin.mpg.de/th/fhi98md/fhi98PP/

PARATEC output for BerkeleyGW is controlled by flags 
gw_shift, gwc, gwr, gwscreening and vxc_matrix_elements.
The flags can be combined with an underscore: e.g. output_flags gwr_gwscreening

gw_shift q1 q2 q3
 -- generates q-shifted grid, q-vector is in crystal coordinates
    in units of reciprocal lattice vectors (for WFNq, WFNq_fi)
    This variable does the same job as the kgrid.x utility.

output_flags gwc
 -- writes complex wavefunctions in G-space for systems without
    inversion symmetry to file WFN (for all codes)

output_flags gwr
 -- writes real wavefunctions in G-space for systems with
    inversion symmetry to file WFN (for all codes)

output_flags gwscreening
 -- writes charge density in G-space to file RHO,
    exchange-correlation potential in G-space to file VXC,
    and matrix elements of exchange-correlation potential to file
    vxc.dat (for Sigma)

vxc_matrix_elements diagmin diagmax offdiagmin offdiagmax
 -- specifies the range of bands for which to compute diagonal and
    off-diagonal matrix elements of exchange-correlation potential
    (for Sigma, in conjunction with output_flags gwscreening)

Other key input flags:

pw_job {scf, nonselfcon}
 -- Use scf for initial calculation, nonselfcon for generating
    BerkeleyGW outputs. (bandstructure does not seem to work)

energy_cutoff ecut
 -- Plane-wave cutoff for wavefunctions, in Ry.

number_kpoints
 -- set to 0  to use k_grid and reduce with symmetries
    set to -1 to use k_grid and do not reduce with symmetries
    set to any other number to read from file KPOINTS

k_grid nx ny nz
 -- 3 integers specifying Monkhorst-Pack k-grid dimensions

k_grid_shift dx dy dz
 -- Monkhorst-Pack k-grid shifts (typically 0.0 or 0.5)

number_bands nb
 -- Number of bands to use in calculation. Fraction actually useful
    or written to BerkeleyGW output determined by next variable.

eigspacefrac frac
 -- Fraction of bands to converge. Setting a higher number_bands
    and lower eigspacefrac can make the calculation more efficient
    depending on the diagonalization scheme. 0 < frac <= 1.0.

You can find the actual input files for PARATEC and BerkeleyGW in 
examples/DFT, in PARATEC subdirectories for each example.

There are also bgw2para and rho2cd utilities that convert 
BerkeleyGW files WFN and RHO to PARATEC format. This may be 
useful, for example, if one generates the plane waves on top of the 
valence and conduction bands (look into MeanField/SAPO/README for details) 
and wants to diagonalize them further in PARATEC. There are no input 
files; bgw2para takes as argument the wfn filename,
and it creates files WFN$n.$s and BAND needed for PARATEC. 
Similarly, rho2cd requires file RHO and it creates file CD.